Rectifier
GA1814
Test notes: To test the rectifiers, use the regulators testing modulePositive heat sink test:• Connect the black cable to the positive heat sink and touch the tip of the orange cable to each of the phases (U, V, W). The “PILOT” lamp should come on when touching the orange cable to each phase.• Reverse the connections, securing the orange cable to the positive heat sink and touch the tip of the black cable to each of the phases (U, V, W). Now the “PILOT” lamp should not light up when touching the black cable to each phase.