Voltage Regulator
GA594

Test notes: Regulators with "DFM", "FR", "LI" terminal - regulator pulse output terminal to the vehicle's Electronic Control Unit to inform about the regulator’s functioning. To check its operation, use the sensors test module in the Frequency function. Using the PU02 cable set, connect the green tip to the "IN" input and the red tip to the "+ 5V REF" input, then connect the green alligator clip to the DFM, FR or LI terminal attached with the red alligator clip (+ 5V REF). Perform the regulator test and, during the test, the DFM (FR, LI) signal output frequency and the percentage of the time that the signal remains high should appear on the LCD screen of the sensors test module.

Set Point: 14,5

Product info »

Related products:

Rectifier
GA1813

Autoparts
Electrical parts

Category: Electrical parts » Rectifier

Replaces: TRANSPO: MER523

Application: KIA: Soul 2.0L; HYUNDAI: I-30 2009->, Elantra 2.0 2007-20...

Regulator assembly: GA921 / GA594

Number of diodes: 6X50A

Compare

Compare up to 3 products

Preloader